Chapter Four · failure evidence

What Cyclic Voltammetry (CV) got wrong, from 28 dissertations

Across the records, cyclic voltammetry frequently encounters severe measurement challenges caused by background currents, solvent window limits, and high scan rate distortions. Researchers also encounter difficulties when overlapping processes, complex electrolyte matrices, and unmodeled reaction kinetics prevent the accurate extraction of thermodynamic and kinetic parameters. These records come from PhD theses at 16 institutions, 2021 to 2026. Each links to its thesis. They were extracted by language models reading the full text, so treat each as a lead to read, not a verdict.

Parasitic electrolyte reactions and capacitive currents mask Faradaic signals

5 theses · 5 institutions

Target electrochemical signals are frequently masked when background currents from the electrolyte or electrode dominate the measurement. Sub-picoampere Faradaic currents and low surface concentrations are easily obscured by capacitive charging, solvent reactions, or spurious gas evolution.

Tried and failed

cyclic voltammetry applied to organic ligand redox characterization. Outcome: no signal. Reason: redox currents were undetectable due to overlapping background processes

Synthesis and characterisation of conductive metal-organic framework materials · Oxford

Tried and failed

cyclic voltammetry applied to atomically thin 2D heterostructures. Outcome: no signal. Reason: Sub-picoampere electrochemical currents were dominated and obscured by parasitic electrolyte background reactions

The Physics of High-Temperature Superconducting Cuprates in van der Waals Heterostructures · Harvard

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) and linear sweep voltammetry (LSV) for electrode current-potential characterization due to large capacitive currents; multistep chronoamperometry was selected instead.

Novel electrode fabrication and reactor design for electrocatalytic nitrate and nitrite reduction in drinking water treatment · UT Austin

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry for monitoring intercalation because sub-picoampere currents were swamped by parasitic electrolyte reactions, choosing in-situ Hall potentiometry instead

The Physics of High-Temperature Superconducting Cuprates in van der Waals Heterostructures · Harvard

Tried and failed

cyclic voltammetry applied to surface ligand desorption on nanocrystals. Outcome: no signal. Reason: low sensitivity and low surface ligand concentration obscured desorption signals

Metal-ligand bond strength determines the fate of organic ligands on the catalyst surface during the electrochemical CO(2)reduction reaction · EPFL

Tried and failed

in situ liquid-cell cyclic voltammetry applied to uncleaned nanoparticle-modified microelectrodes. Outcome: no signal. Reason: surface contamination caused spurious gas evolution obscuring characteristic electrochemical redox peaks

In situ electron microscopy of nanomaterials dynamics in heterogeneous phase environments · MIT

High scan rates cause ohmic drop distortions and instrument overload

5 theses · 4 institutions

Operating at elevated scan rates introduces severe peak broadening, uncompensated resistance drop, and significant capacitive currents. These kinetic and experimental limitations produce switching artifacts, degrade measurement stability, and can overload the data acquisition hardware.

Tried and failed

physics-informed Bayesian model hypothesis testing applied to electrochemical cyclic voltammetry classification. Outcome: did not generalise. Reason: kinetic limitations, uncompensated resistance drop, and unmodeled capacitive charging currents at faster scan rates

Voltammetric Methods Augmented with Physical Models and Statistical Inference · MIT

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (20 mV/s) for liquid cell degradation studies because high scan rate causes mass transport limitations and peak broadening, failing to match galvanostatic battery degradation

Towards reproducible lithium-ion battery cycling using liquid-phase transmission electron microscopy · EPFL

Tried and failed

Fast scan cyclic voltammetry at high potentials applied to analyte detection in HEPES buffer. Reason: Buffer introduced a large negative switching peak artifact when scanning up to high anodic potential.

Electroanalytical engineering strategies for monitoring molecules in neuroscience · Imperial

Tried and failed

carbon nanotube modification of carbon paste electrodes applied to fast-scan cyclic voltammetry sensing. Outcome: unstable. Reason: excessive noise and uncontrollable sensitivity overloaded the data acquisition system

Novel engineering and characterization of sensing materials and fluidic devices for neuroscience · Imperial

Considered and rejected

Considered and rejected: Rejected extracting ET rate constants at high overpotentials via fast-scan cyclic voltammetry (Laviron method) due to uncorrectable iR drop distortion and potential SAM oxidative desorption.

Infrared Spectroelectrochemical Studies of Redox-Active Self Assembled Monolayers: Structure and Kinetics · HARVEST

Target redox couples fall outside the accessible solvent potential window

5 theses · 5 institutions

Molecules often fail to exhibit detectable redox waves because their formal potentials lie outside the accessible potential window of the electrolyte. Extending the potential sweep window cannot resolve features when high electron affinities or solvent breakdown limits prevent redox cycling.

Tried and failed

solution cyclic voltammetry applied to free organic capping ligands. Outcome: no signal. Reason: ligands exhibited no redox activity or formal electroreduction across the tested potential window

Metal-ligand bond strength determines the fate of organic ligands on the catalyst surface during the electrochemical CO(2)reduction reaction · EPFL

Tried and failed

electrochemical reduction characterization via cyclic voltammetry applied to uranyl Schiff base coordination complexes. Outcome: no signal. Reason: redox couples fell outside the electrochemical solvent potential window

Synthesis and Characterization of Acyclic Schiff Bases and Redox Active Chelation of Actinides · Texas Tech

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) for HOMO determination in Chapter II because many BBOs did not exhibit a redox cycle within the solvent window, using UPS instead.

The evolution of linear and cross-conjugated benzobisoxazole organic semiconductors designed for organic light-emitting diode application · OpenBU

Tried and failed

widening cyclic voltammetry potential sweep window applied to single-peak iron macrocycle electrocatalysts. Outcome: no signal. Reason: extended potential ranges did not reveal hidden redox desorption features for single-peak complexes

Oxygen reduction on iron macrocycles kinetics study and engineering of the electrochemical interface · Imperial

Tried and failed

electrochemical cyclic voltammetry in aqueous electrolyte applied to conjugated copolymer with high electron affinity. Outcome: no signal. Reason: electron affinity was too high to permit redox response in aqueous solution

Design, Synthesis, and Characterization of Electron Transporting DPP-based Copolymers for Application in Organic Electronics · Georgia Tech

Complex matrices and overlapping reactions distort target redox peaks

4 theses · 4 institutions

Complex electrolyte environments and multi-component systems introduce interfering peaks that obscure the primary analyte response. Contact with polar solvents, cell culture media, or concurrent processes such as bulk oxygen intercalation alters energy levels and distorts electrochemical signatures.

Considered and rejected

Considered and rejected: Rejected cyclic voltammetry (CV) for measuring dye frontier orbitals because polar electrolyte solvents altered energy levels upon contact with thin films

Bridging the gap between stability and performance of next-generation light-converting materials · ResearchWorks

Considered and rejected

Considered and rejected: Rejected measuring catalyst cyclic voltammetry redox potentials due to excessive unknown peaks from oxidized catalyst forms and ligands.

Anti- Bacterial Properties Of Bisphenolic Honokiol Derivatives · Penn

Considered and rejected

Considered and rejected: Rejected using fast cyclic voltammetry for quantifying intrinsic OER activity on oxygen-deficient perovskites because currents from bulk electrochemical oxygen intercalation overestimate catalytic activity; used steady-state galvanostatic measurements instead.

Activity and Stability Design Principles of Transition Metal Compounds for Decarbonization · MIT

Tried and failed

Fast scan cyclic voltammetry at microelectrodes applied to analyte detection in cell culture media. Outcome: no signal. Reason: Complex media components caused severe peak broadening, positive potential shifts, and attenuated oxidative current.

Electroanalytical engineering strategies for monitoring molecules in neuroscience · Imperial

Quantitative parameter extraction fails due to insufficient precision and coupled kinetics

4 theses · 3 institutions

Researchers struggle to extract reliable standard potentials and transfer coefficients due to limited overpotential ranges and experimental precision. Poorly defined onset potentials and unknown coupled background reaction mechanisms further hinder accurate kinetic modeling.

Tried and failed

direct cyclic voltammetry on sensing electrode applied to standard reduction potential determination. Outcome: data insufficient. Reason: could not acquire standard potential with sufficient precision under experimental conditions

Diagnosing Band-Mediated Electrochemical Half-Reaction Mechanisms and Identifying the Unique Features Thereof · MIT

Tried and failed

variable scan rate cyclic voltammetry trumpet plots applied to interfacial electron transfer kinetic parameter extraction. Outcome: data insufficient. Reason: limited overpotential perturbation ranges prevented reliable extraction of transfer coefficients

Mechanistic Studies of Interfacial Proton-Coupled Electron Transfer to Molecularly Defined Surface Sites · MIT

Considered and rejected

Considered and rejected: Rejected onset potentials in voltammetry for calculating standard electrochemical potentials because onset potentials are poorly defined and sensitive to temperature and ohmic currents.

Sulfones and side chains: structure-function-performance relationships in linear conjugated polymer photocatalysts for the evolution of hydrogen from water · Imperial

Considered and rejected

Considered and rejected: Rejected full cyclic voltammetric wave analysis (peak potential/current) for extracting acetic acid dissociation parameters in favor of steady-state limiting current analysis at a microelectrode to avoid requiring unknown hydrogen evolution reaction kinetics/mechanisms on Pt electrodes.

Computational electrochemistry · Oxford

Left open by the authors

Problems the authors named and did not get to.

Left open

Test pCOOH-DPPTz-BTh films via cyclic voltammetry in aqueous electrolyte to assess electrochemical stability and measure OECT device performance. Blocker: Requires synthesized polymer samples and physical wet lab electrochemical/transistor testing apparatus.

Design, Synthesis, and Characterization of Electron Transporting DPP-based Copolymers for Application in Organic Electronics · Georgia Tech

Left open

Resolve the discrepancy in current peak magnitudes between cyclic voltammetry and differential pulse voltammetry measurements during oligomer degradation. Blocker: Requires wet lab electrochemical experiments (CV and DPV) and physical samples undergoing oligomer degradation.

Thin-film transistor : characterization, scaling studies, and applications in electrochemical charge sensing · UT Austin

Left open

Elucidate mechanistic pathways and obtain cyclic voltammetry profiles for direct and NaCl-mediated electrochemical oxidations of amines. Blocker: Requires wet-lab electrochemical equipment and cyclic voltammetry experiments

An Electrochemical Oxidation Prins-type Cyclisation Sequence for the Synthesis of Substituted N-Heterocycles and Copper-Catalyzed Conjugate Addition Towards Hydnocarpic Acid Synthe · Research Repository UCD

Left open

Investigate low-potential current density increases observed during cyclic voltammetry of P(EO-MO) electrolytes with LiTFSI. Blocker: Requires a wet lab with polymer synthesis capabilities and electrochemical cyclic voltammetry equipment.

Developing Dynamic Plastics for Improved Sustainability and Energy Storage Technologies · Cornell

Left open

Perform cyclic voltammetry on 5,6,9,10-tetramethoxy-2-methylphenanthro[9,10-b]thiophene to determine the mechanism of the second oxidative annulation. Blocker: Requires wet lab electrochemistry equipment and synthesized chemical intermediate (5,6,9,10-tetramethoxy-2-methylphenanthro[9,10-b]thiophene).

Part 1: Structure-Property Relationships of Regioregular Poly(3-alkylthiophene)s Bearing Branched Side Chains Part 2: Ferric Chloride-Promoted Oxidative Annulation of 3,3’,4,4’-Tet · Georgia Tech

Left open

Identify and test negative electrolytes with redox potentials between -0.3 V and -0.6 V for acidic Fe-QA redox flow batteries. Blocker: Requires wet chemistry lab, chemical synthesis, and electrochemical full-cell testing hardware

Development of Iron Complex-based Aqueous Redox Flow Batteries for Large-scale Energy Storage · Harvard

Left open

Characterize square wave voltammetry on bipolar electrodes to background-subtract capacitive charging current. Blocker: Requires a physical electrochemical wet lab and bipolar electrode apparatus

Development of electrochemical and electrokinetic methods to improve the sensitivity of diagnostic devices: 1) periodic voltammetry on bipolar electrodes and 2) electrokinetic enri · Iowa State

Left open

Develop deconvolution or Fickian diffusion models to separate overlapping secondary insulin and serotonin oxidation peaks from fast-scan cyclic voltammograms. Blocker: Requires experimental FSCV voltammogram datasets from bevelled carbon fiber microelectrodes or wet lab electrochemistry equipment.

Electroanalytical engineering strategies for monitoring molecules in neuroscience · Imperial

Left open

Develop statistical variance models for voltammetric current measurements incorporating baseline drift and capacitive effects. Blocker: Requires experimental voltammetry data with known ground-truth noise profiles or a wet lab to collect calibration datasets

Voltammetric Methods Augmented with Physical Models and Statistical Inference · MIT

Left open

Apply Partial Least Squares deconvolution to resolve overlapping DPASV voltammograms and copper interference on gold screen-printed electrodes. Blocker: Requires experimental stripping voltammetry dataset with complex overlapping peaks and copper interference on Au SPEs.

Electrochemical method for the rapid in situ screening of heavy metals in soil and water samples · Cranfield

Checking a claim in this area?

We can run the same search on any method or claim. If nothing turns up, we will say so, and that proves nothing on its own.